Two official documents now do most of the work when anyone asks whether a spray foam roof was installed properly. One tells homeowners what to do. The other explains, in detail, what a moisture-safe installation looks like. Both are quoted often and read rarely.
This guide goes through each of them, says which document every point comes from, and is plain about what neither of them can tell you. We do not install spray foam and we do not remove it.
The documents, and what each one is
| Document | Published by | What it is | What it is not |
|---|---|---|---|
| “Spray foam insulation: Remediation, removal and lending” | Department for Energy Security and Net Zero, 22 October 2026 | Government guidance for homeowners who already have spray foam | An installation standard. It does not say how foam should be fitted |
| “Spray foam insulation applied to timber sloped roofs in dwellings” | Health and Safety Executive, as the Building Safety Regulator, February 2024. Started by the then Department for Levelling Up, Housing and Communities | Computer modelling of moisture risk in timber roofs insulated with spray foam | Government policy or regulation. The report says its conclusions are the authors’ own. It is also not a survey of real roofs |
| BS 5250:2021, “Management of moisture in buildings. Code of practice” | British Standards Institution | The British Standard the research measures spray foam against | Written about spray foam. The report notes that it does not refer to any particular insulation product |
What the government’s October 2026 spray foam guidance says
- Spray foam “can be used effectively in many settings”, but it “is not always the right product for some homes and may need to be fixed or removed”.
- Before making any decision, take advice from a specialist surveyor. The guidance says only specialist surveyors experienced in spray foam can tell you whether the foam should be removed.
- It points homeowners to the Property Care Association’s find-a-specialist tool, and says the surveyor should be familiar with the Spray Foam Insulation Inspection Protocol of March 2023.
- Installations under government schemes since 2020 must have been carried out by TrustMark-registered installers.
- If there is a problem with one of those installations, it was completed less than six years ago and the installer is still trading, you can use TrustMark’s dispute resolution process. If the installer has gone, the route is the insurance-backed guarantee, which the guidance says typically may last up to 10 years.
- Keep your installation paperwork. If you do not have it, the installer or manufacturer should be able to supply it.
- Removing the foam “will not always guarantee” that a lender will lend, and improper removal could lead to further issues.
- Cold calls and unsolicited offers to sell or remove foam have increased. They can be reported to Trading Standards.
Notice what is missing. The guidance does not describe how foam should be installed. For that you need the second document.
How spray foam roof insulation should be installed
The HSE research judged spray foam against the roof designs in BS 5250:2021. Two terms make the rest easy to follow.
- Underlay. The layer directly beneath the tiles or slates. Older roofs usually have bitumen felt, which the standard calls a high resistance underlay because water vapour does not pass through it easily. Newer roofs often have a breathable membrane, a low resistance underlay.
- Air and vapour control layer. A layer on the warm, room side of the insulation that stops moist indoor air getting into it. In the research this was foil-backed plasterboard.
The standard’s guidance for an insulated roof slope, as the report sets it out:
Where the underlay is bitumen felt:
- a vapour control layer on the warm side of the insulation
- a ventilated gap between the felt and the insulation, at least 25mm deep and ventilated at both high and low level. Allowing 15mm for the felt sagging between rafters, the report gives a design gap of 40mm
Where the underlay is a breathable membrane, one of two options:
- a vapour control layer on the warm side, with an air gap in the batten space above the membrane where the roof covering lets air through, as traditional tiles do
- where a vapour control layer is not practicable, a ventilated gap between membrane and insulation, as for felt
Spray foam sticks to whatever it is sprayed onto, so how is a gap left? The report answers that directly: the space can be formed with card spacers fitted between the rafters before spraying, or similar techniques.
Its headline finding is that the risks are low when open-cell foam, which lets moisture pass, is applied in line with these designs.
In plain terms, then, the installation the research supports is open-cell foam, kept off the back of the tiles and the underlay by a gap, ventilated from the eaves where the underlay is felt, and lined on the room side with a vapour control layer.
The report adds a caution of its own. It says spray foam as it is applied in practice may not follow this guidance, and that where a measure such as the vapour control layer is left out, the moisture risk has to be properly modelled for the conditions that roof is in.
What the research found about spray foam loft insulation installed other ways
The researchers also modelled foam applied directly to the underlay or the tiles, with no gap, for two climates: London, and Newcastle as a more severe one. Risk was graded by predicted decay in the outer part of the rafter, the part nearest the roof covering, over five years. High means more than 25% predicted decay, medium between 1% and 25%, and low under 1%.
| How the foam was applied (no gap) | London | Newcastle |
|---|---|---|
| Onto breathable membrane: open-cell, no vapour control layer | Low | Medium |
| Onto breathable membrane: closed-cell, no vapour control layer | Low | Medium |
| Onto breathable membrane: open-cell, with vapour control layer | Low | Medium |
| Onto breathable membrane: closed-cell, with vapour control layer | Low | Low |
| Onto bitumen felt: open-cell, no vapour control layer | High | High |
| Onto bitumen felt: closed-cell, no vapour control layer | Low | High |
| Onto bitumen felt: open-cell, with vapour control layer | Low | Medium |
| Onto bitumen felt: closed-cell, with vapour control layer | Low | Low |
| Directly onto tiles or slates: either foam, with or without a vapour control layer | High | High |
Three things stand out.
- Foam on the back of the tiles was high risk every time. Either foam, either climate, with or without a vapour control layer. The report says the risk extends to the tile battens as well as the rafters.
- Open-cell foam on bitumen felt with no vapour control layer was high risk in both climates.
- Where you live matters. Of the seven installations graded low in London, five were graded medium or high in Newcastle.
Other findings on open-cell and closed-cell spray foam insulation
- Old loft insulation left in place. Where open-cell foam was added and the original insulation stayed on the loft floor, the modelling found a significant risk of mould growth on the inside face of the rafters, in both climates. With a thick layer left (300mm was modelled), condensation on the surface of the foam became possible in warmer periods.
- Eaves vents. Leaving the eaves vents open reduced the mould risk, but the report says the thermal benefit of the foam would then be significantly diminished.
- Leaks and gaps. A roof covering that lets rain in, or small gaps between the foam and the rafters, raised the risk of condensation on the cold side of the insulation. The report says these risks are likely to be highest with closed-cell foam.
- Thickness. Foam was modelled at 100mm and 200mm. The risk grade did not change, but humidity in the outer layer tended to be higher with the thicker foam.
- The roof on its own. Insulating the roof slope as a single measure, without looking at the rest of the house, runs against the whole-building approach in BS 5250:2021. The report says that under PAS 2035, the specification for energy-efficiency retrofit of homes, a retrofit coordinator would be likely to question changing a cold loft to an insulated roof slope when re-insulating at ceiling level may be more appropriate, unless the loft is becoming a room.
That last point matches the advice in our guide to re-insulating after spray foam removal.
What the research cannot tell you
It is worth being as careful with this report as its authors were.
- It is modelling. Nobody inspected roofs for it. It predicts risk from the physics of heat and moisture.
- It covers two locations in England. London and Newcastle. Nowhere else was modelled.
- It rests on stated assumptions about the roof. The report says every household is unique and that it cannot account for variations from those assumptions.
- It uses present-day climate data, and the report says the results may not reflect the effect of climate change.
- It is not policy. The conclusions are the authors’ own.
Above all, it cannot tell you the condition of your roof. A high-risk category is not a finding of rot. A low-risk category is not a clean bill of health.
How to read your own spray foam installation against the guidance
These are the questions the research turns on. Some you can answer from the loft hatch or your paperwork. The rest are for a surveyor.
- Is it open-cell or closed-cell? See how to tell if you have spray foam insulation and open-cell vs closed-cell spray foam removal.
- What was it sprayed onto? The back of the tiles or slates, black bitumen felt, or a breathable membrane.
- Was a gap left behind the foam? This is rarely visible from inside the loft. The installation paperwork or the installer may say.
- Is the foam lined on the room side, or open to the loft?
- Was the old loft-floor insulation left in place?
- What paperwork do you have? The industry’s joint consumer guide says a handover pack should include a pre-installation roof evaluation, a hygrothermal evaluation (the moisture risk assessment), the product’s BBA or KIWA accreditation, the installer’s details and the guarantees.
Take the answers to a specialist surveyor, as the government’s guidance says. Do not diagnose the roof yourself from a table, and do not let a salesman do it for you either.
Is spray foam insulation safe?
The honest answer from these documents is that it depends on the roof and on how the foam was installed. The government says it can be used effectively in many settings. The House of Commons Library reports the government’s position that foam installed in line with the relevant standards should not need to be removed. The research shows what “in line with the standards” means in practice, and how quickly the risk rises when foam goes straight onto felt or tiles.
Nobody can settle it for a particular house without looking. See do I need to remove spray foam insulation.
How this shapes the way we work, and why we require a RICS sign-off
We are a free, independent advisory service. We carry out no installations and no removals, so we have no reason to tell you a roof needs more work than it does. The research supports the way we work in three respects.
We do not decide anything from the word “foam”. Whether removal is even the question depends on the foam type, the surface it is on, the gap, the lining and the paperwork. So our process starts with a call to establish what is installed, followed by a written summary, and an honest view on whether removal may be needed at all. The decision on that belongs with a specialist surveyor.
When we vet removal companies, we make sure an independent RICS surveyor’s sign-off on completion is part of what they do. The research grades risk in the outer part of the rafter, nearest the roof covering. That is exactly the part nobody can inspect while foam is in place. If the foam does come out, the day it comes out is the first time anyone can see that timber. A contractor’s completion certificate is the contractor confirming its own work. A RICS surveyor is independent, inspects the stripped roof and puts their professional name to its condition, in a form that buyers’ surveyors, conveyancers and lenders recognise.
The money stays with you until the work has been checked. We source three quotes from vetted spray foam removal companies, compare them with you line by line, and pass your details only to the company you choose. No vetted company takes a deposit. The contractor sends its completion report to your advisor, you review it together, and you pay only after that sign-off. Our guide to hiring spray foam removal contractors sets out the full process.
A surveyor’s report does not guarantee any lender’s decision. Lenders decide case by case.
Need clarity on this? Ask a specialist.
This article covers government guidance on spray foam roof insulation. If you’re unsure how it applies to your own home, send your question — a specialist in this field will come back to you with a straight answer. Free, independent, no sales.
Prefer to talk it through? 0800 494 7163 — free, Mon–Fri 9am–5pm.
Quick answers
Does the government say spray foam insulation must be removed? No. The October 2026 guidance says spray foam can be used effectively in many settings, and that a specialist surveyor should advise before any decision.
Is there a British Standard for spray foam roof insulation? BS 5250:2021 covers the management of moisture in buildings for any insulated roof. The HSE research notes that it does not refer to spray foam by name.
Can spray foam be sprayed directly onto roof tiles? In the HSE research, foam applied directly to tiles or slates was high risk in every scenario modelled.
Does open-cell spray foam need a vapour control layer? The BS 5250:2021 guidance summarised in the report recommends one on the warm side of the insulation. In the modelling, open-cell foam on bitumen felt without one was high risk in both climates.
Is closed-cell spray foam lower risk than open-cell? Not simply. Closed-cell graded low in more of the direct-application scenarios, but the low-risk finding for a standard-compliant roof was for open-cell foam, and the report says the risks from leaks and gaps are likely to be highest with closed-cell.
Who can tell me whether my spray foam was installed correctly? A specialist surveyor experienced in spray foam. The government points to the Property Care Association’s find-a-specialist tool.
National Spray Foam Advisory is a free, independent advisory service. We carry out no installations and no removals. We are not regulated to give mortgage advice. This article summarises published documents and is not a survey of any property. Every home and every installation is different.
Sources: GOV.UK, Department for Energy Security and Net Zero, “Spray foam insulation: Remediation, removal and lending” (22 October 2026) · Health and Safety Executive (Building Safety Regulator), “Spray foam insulation applied to timber sloped roofs in dwellings” (February 2024) · BS 5250:2021, “Management of moisture in buildings. Code of practice”, as summarised in the Health and Safety Executive report · Spray Foam Insulation Consumer Guide (Property Care Association, Insulation Manufacturers Association, Residential Property Surveyors Association and others, May 2025) · House of Commons Library briefing CBP-10658, “Spray foam insulation and mortgages”.